There are different meaning of FM-2acronym in the table which are compilation of FM-2abbreviation such as IT Terminology etc. FM 2was invented by Dupont - it is actually an HFC (HeptaFluoro Propane) it is HFC 227. FM2is a Celan Gas Agent. Previously it was used for Asthama Patients.
Agent – FM-2(HFC-227ea) is a clean, gaseous agent containing no particles or oily residues. FM-2leaves no residue or oily deposits on delicate electronic equipment, and can be removed from the protected space by ventilation. By definition, an automatic fire suppression system can operate without human intervention. In many systems, detection is accomplished by mechanical or electrical means.
HFC-227ea is a fast acting clean agent fire suppression gas with a wide range of benefits and applications. FM 2is a fast reacting, effective, clean agent system that can reduce the damage of a fire as it leaves behind no residue. FM 2fire suppression is also known as HFC227ea.
Even one day lost to fire-related downtime can mean lost revenues, customers and profits. You know you should protect against fire. But, basic water type fire suppression systems (sprinklers) can cause even more damage than the fire itself.
Gaseous clean agent fire suppression systems have long been the answer to protecting. These systems absorb heat, which increases the fire suppression process. They are environmentally acceptable to the EPA. FM 2is heptafluropropane (HFC 227) this is clean agent used for the fire protection in the critical areas like Data centre,computer room ,art gallery etc This stores in a cylinder in liquid form upto bar pressure when fire alarm triggers after sec it will release in the vapor state this having ODP(ozone depleting Potential ) zero.
It is stored as a liquid and dispensed into the hazard as a colourless, eclectically non-conductive vapour that is clear and does not obscure vision. It leaves no residue and has acceptable toxicity for use in occupied spaces at design concentration. Service for FM-2Systems Western States Fire Protection can help to design, install, and provide ongoing service for your FM-2system. The present understanding of the operation of FE2and FM-2is that of it’s fire fighting effectiveness is achieved through heat absorption and through direct chemical means (action of the fluorine radical on the chain reaction). This is a single volume technical manual arra nged in sections, followed by an Appendix.
The discharge dynamics for Inerts versus Halocarbons are different and should be considered when designing any type of gaseous extinguishing system. Our Clean Agent Fire Protection System, which includes the use of HFC-227ea and FM-20 leaves no residue and doesn’t require costly clean-up, unlike sprinklers and other fire protection systems. Currently FM 2is meant to be replacement with significantly reduced ozone depletion potential. FM-200’s physical properties lower the flame temperature, while the chemical action suppresses flame propagation. In fact, FM-2is the appropriate choice in applications where liquid extinguishants, water-based or dry chemical products can cause costly damage or result in considerable and expensive downtime.
Get XML access to fix the meaning of your metadata. Step Identify the hazard to protect and note the applicable design concentration number. Example: Hazard is Class (Electrical) = 7. Round up to whole number = L = ft.
Call the manufacture But, not sure how many years before the cylinder needs a hydro? So the contents would need to be remove but might be able to reuse the agent. FM - 2Clean Agent Fire Suppression System.