How does a deluge valve system work? What are deluge fire sprinkler systems? What temperature do sprinklers activate? Deluge Fire Sprinkler System.


The detection system is installed in the same area as the sprinklers.

When the detection system is activated water discharges through all of the sprinkler heads in the system. A deluge fire protection system has unpressurized dry piping and open sprinkler heads. The valve is opened when activated by a heat or smoke detection system. They are composed of open sprinklers attached to a piping system that is connected to a water supply through a heat responsive valve.


When this valve opens, water is discharged into the piping system and through the open sprinklers. In a deluge sprinkler system , water is held back in a separate supply zone, and is not sitting within the piping itself that connects with the sprinklers. Next, choose a releasing trim and releasing device(s) depending on your application.

Interconnecting gas leak detection with deluge. A sprinkler system employing open sprinklers attached to a piping system connected to a water supply through a valve that is opened by the operation of a detection system installed in the same areas as the sprinklers. When the system detects heat and or fire, the deluge valve will release water, dry chemicals, inert gases, or foam. Try t olearn from my videos. I have added below for more information.


NFPA members and public sector officials may submit a question on an NFPA code or standard. Responses are provided by NFPA staff on an informal basis. The function of the deluge valve system was to distribute pressurized water to either open type nozzles or fire water monitors. A deluge system is a water mist system using open spray heads attached to a piping system that is connected to a water supply through a valve that is opened by means of a detection system installed in the same area as the spray heads. They are attached to a deluge pipe that is connected to a main water supply.


This valve is opened by the operation of a fire detection system installed in the same areas as the open sprinklers or nozzles. The system is connected to a water supply through the deluge valve. Manual opening of the control valve should be set warning signs to prevent artificial operation. So for that matter they are more complex.


Detection systems can include heat, smoke, ultraviolet (UV), or infrared (IR).

We offer fire protection systems and services to customers throughout the United States. Oftentimes, deluge systems are used in conjunction with foam concentrate which further controls certain types of fire. These systems are used for special hazards where rapid fire spread is a concern, as they provide a simultaneous application of water over the entire hazard. Using an innovative detection system that recognizes smoke or heat, this fire suppression installation activates a valve that releases water to all sprinklers. SIRON Fire Protection Services will bring a fully equipped container on the platform or the production location.


This detector ring is placed next to the most likely sots where the temperature is about to exceed or fire is about to take place. Also the, entire transformer is surrounded by multiple sprays, at multiple levels. A spray is nothing, but a sprinkler without the temperature sensing, bulb. A deluge system is similar to other types of sprinkler system except that the chemical is released through open discharge devices rather than spray heads.


This fire suppression system is activated by smoke or heat detectors and releases a flood of foam instantly from an open sprinkler, nozzle, or foam generator.