Friday, 6 October 2017

Condensate pot

When a condensate pot is neede there’s a time-saving solution many plant engineers don’t know about. They provide an interface between the vapour phase and the condensed phase in the impulse lines. However, additional problems are introduced when measuring steam.


Generally Steam is passed through Condensation Pots. Stainless Steel to ASTM A 3Piping code, Pand other alloy steel fabricated from Seamless pipe with inside cleaned and checked to assure desired volume.

The main purpose of condensate pot is to catch and hold condensate and foreign material. The condensate may be drained from the bottom valve connection. What is the condensate trap? How to size a condensate return unit? When installed correctly, these simple devices can significantly improve flow measurement accuracy in differential pressure measurement systems by providing an interface between the vapour and liquid phases.


OSY gate or ball valves to be used as the drain port. The bottom connection is used as a drain port to remove condensate. Special features Seal and condensate pots are manufactured from seamless pipes with welded and hot-formed caps.

Standard pipe sizes are 2″ to 6″. When the condensate enters the boiler feed pump additional chemicals are added and the product is now called boiler feed water. Condensate pots are mainly used for the measurement of steam. Without the chamber, the condensate can evaporate at times and provide different liquid levels that affect the flow measurement.


Use stainless steel tubing for the connection to the flanges or steam line. Place the pot nearer to the steam line or flange connection points. This helps keep manifold orifices clean and free of foreign material.


They are located upstream of the instrument and have a bottom drain so that they may be cleaned. Singlaatul do not complicate yourself. The seal pot is introduced to the pump seal chamber through various piping plans, often in compliance with sealing system standard API 682.


The liquids are considered buffer fluids if the seal pot is unpressurized (Piping Plan 52). More specifically, maintained at a pressure less than the seal chamber pressure and less than PSI ( bar). CONDENSATE POT are widely used in various application industries like various purposes and has numerous applications such as refineries, Power Plants, Chemical and Petrochemical, Steel Plants and other process industries. Blowing down these lines periodically ensures that collection of debris is prevented from impacting the measurement accuracy.


SEAL POTS (sometimes called condensate pots) are used to allow a liquid seal between the instrument and flowing gases such as steam. Their function is to keep the liquid level constant in the impulse tubes. Scribd is the world's largest social reading and publishing.

It is just to easy in maintenance. The role of steam distribution lines is to reliably supply steam of the highest reasonable quality to the steam-using equipment. In order for this to be achieve condensate must be removed quickly and efficiently through steam traps installed in proper condensate discharge location (CDL) installations. Accumulation of condensate in reboilers increases the risk of corro-sion. Chemical treatment of steam to reduce the condensate corrosion poten-tial is discussed in the Chemical Treat-ment and Monitoring Section.


On high pressure boilers, a condensate pot is connected on the top water leg to keep the leg full of condensate. If the condensate level varies in the top connected leg, the drum level measurement will not be accurate. On low pressure boilers, a condensate pot may not be required.